• ACSR 75mm2 to Kenya (7/1*4.09mm) as Per BS215
  • ACSR 75mm2 to Kenya (7/1*4.09mm) as Per BS215
  • ACSR 75mm2 to Kenya (7/1*4.09mm) as Per BS215
  • ACSR 75mm2 to Kenya (7/1*4.09mm) as Per BS215
  • ACSR 75mm2 to Kenya (7/1*4.09mm) as Per BS215

ACSR 75mm2 to Kenya (7/1*4.09mm) as Per BS215

Application: Construction, Overhead
Voltage: Low and Medium Voltage Cable
Current: AC Cable
Insulation Material: Nude
Sheath Material: Nude
Material Shape: Round Wire
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
ACSR
Wire Core Material
Aluminum
Certification
ISO, CCC, CE, RoHS, VDE
Model
ACSR
Brand
Jinshui
Applicable Standard
BS215
Destination
Kenya
Transport Package
Wooden Drum
Specification
1.1*0.55*0.5*06
Trademark
Jinshui
Origin
China
HS Code
8544492100
Production Capacity
5000km/Mouth

Product Description

Product Description

 

Applications 
Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity. 

Construction 
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corer or infusion of the complete cable with grease. 

Specifications 
ACSR bare conductor meets or exceeds the following ASTM specifications: 
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes 
B-231 Aluminum Conductors, Concentric-Lay-Stranded 
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR) 
B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW) 
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ) 
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR) 

Notes 
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions. 
Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.
 

Code name Nominal area
(mm2)
 Stranding and wire diameter
 
Approx overall diameter Rated strenght Max.DC resistance of conductor at 20ºC 
aluminuium Steel mm kN ohm/km
No./mm
Mole    10 6/1.5 1/1.5  4.5 4.1 2.7060
Squrrel 20 6/2.11 1/2.11 6.33 7.9 1.37
Gopher 25 6/2.36 1/2.36 7.08 9.6 1.093
Weasel 30 6/2.59 1/2.59 7.77 11.4 0.9077
Fox 35 6/2.79 1/2.79 8.37 13.2 0.7822
Ferret 40 6/3.0 1/3.0 9 15.2 0.6766
Rabbit 50 6/3.35 1/3.35 10.05 18.4 0.5426
Mink 60 6/3.66 1/3.66 10.98 21.9 0.4545
Skunk 60 12/2.59 7/2.59 12.95 52.9 0.4568
Beaver 70 6/3.99 1/3.99 11.97 25.8 0.3825
Horse 70 12/2.79 7/2.79 13.95 61.2 0.3936
Racoon 75 6/4.1 1/4.1 12.3 27.2 0.3623
Dog 100 6/4.72 7/1.57 14.15 32.7 0.2733
Wolf 150 30/2.59 7/2.59 18.13 69.2 0.1828
Dingo 150 18/3.35 1/3.35 16.75 35.7 0.1815
Lynx 175 30/2.79 7/2.79 19.53 79.8 0.1576
Caracal 175 18/3.61 1/3.61 18.05 41.1 0.1563
Panther 200 30/3.0 7/3.0 21 92.3 0.1363
Jaguar 200 18/3.86 1/3.86 19.3 46.6 0.1367
Bear 250 30/3.35 7/3.35 23.45 111.2 0.1093
Goat 300 30/3.71 7/3.71 25.97 135.8 0.0891
Zebra 400 54/3.18 7/3.18 28.62 131.9 0.06057
Elk   450 30/4.5 7/4.5 31.5 198.3 0.06057

ACSR 75mm2 to Kenya (7/1*4.09mm) as Per BS215ACSR 75mm2 to Kenya (7/1*4.09mm) as Per BS215

ACSR 75mm2 to Kenya (7/1*4.09mm) as Per BS215





 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory
Year of Establishment
2017-10-17
Plant Area
2000 square meters