• Hta S26 Extruded XLPE Insulation Medium Voltage Cable NFC33-226 Standard
  • Hta S26 Extruded XLPE Insulation Medium Voltage Cable NFC33-226 Standard
  • Hta S26 Extruded XLPE Insulation Medium Voltage Cable NFC33-226 Standard
  • Hta S26 Extruded XLPE Insulation Medium Voltage Cable NFC33-226 Standard
  • Hta S26 Extruded XLPE Insulation Medium Voltage Cable NFC33-226 Standard

Hta S26 Extruded XLPE Insulation Medium Voltage Cable NFC33-226 Standard

Application: Construction, Underground
Voltage: Low and Medium Voltage Cable
Current: AC Cable
Insulation Material: XLPE
Sheath Material: Crosslinking
Material Shape: Flat Wire
Samples:
US$ 0/Meter 1 Meter(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
MV ABC Cable
Wire Core Material
Tinned Wire
Certification
ISO, CCC, CE, RoHS, VDE
Model
Yjv32
Brand
Jinshui
Transport Package
Wooden Drums
Specification
2.2*1.1*1.0*1.1
Trademark
Jinshui
Origin
China
HS Code
8544492100
Production Capacity
50000m/Day

Product Description

NFC33-226 is a medium voltage power cable with a rated voltage of 12kV to 20kV. The cables are available in single core or 3x1 construction and are suitable for buried, direct burial in soil or free air laying. The cable can be supplied with sheath colors according to the installation code: red for underground connections, gray for aerial, surface/underground and technical applications.

Specifically, product features and parameters of NFC33-226 cables may include:

1.Suitable for medium voltage power system from 12kV to 20kV;

2.Single core or 3x1 (clover) structure available;

3.It can be laid underground, directly buried in soil or in free air;

4.Sheath color can be selected according to installation specifications;

5.Aluminum material as a conductor;

6.XLPE and PE materials as insulation and sheath materials.

Features

  1. It can be applied to medium-voltage power systems from 12kV to 20kV, providing an efficient and reliable power transmission solution;
  2. Single core or 3x1 structure can be provided according to application requirements, which can meet the needs of different circuit connection methods;
  3. It can be laid underground, directly buried in soil or in free air, suitable for different application scenarios;
  4. Different colors of sheaths can be selected according to installation specifications, which helps to distinguish different types of cables and realize management and maintenance;
  5. Aluminum material is used as the conductor, which is not only light in weight and low in cost, but also has good electrical conductivity, thermal conductivity and corrosion resistance;
  6. XLPE and PE materials are used as insulation and sheath materials, which have good performances such as voltage resistance, heat resistance, and welding resistance.

Application

NFC33-226 cables are suitable for medium voltage power systems, with rated voltages between 12kV and 20kV. It can be used as a distribution line to transmit power, lighting and control signals, and can be applied in different scenarios, such as directly buried in the ground, laid in free air or buried in the soil.

More specifically, the application areas of NFC33-226 may include

1.Municipal engineering

Applied in the power distribution network of urban public facilities, streets and other areas

2.Industrial and mining enterprises:

Used in the construction and transformation of power distribution trunk lines in factories, mines and other places;

3.Residential quarters

Used as power distribution lines in residential quarters and villas.

Construction

Medium-voltage power cables have shielding and sheathing, and non-magnetic armoring can be used under necessary conditions. Refer to the figure below for the structure of conventional cables.

Performance

Number of cores ×  Cross-section  Nominal thickness of Insulation Min. outer diameter over sheath Twisted diameter of cable Approx. weight Max. DC resistance at 20ºC Current rating
Underground
Current rating
In air
No.×mm2 mm mm mm kg/km Ohm/km A A
3×1×50 3.4 23.1 53.4 2603 0.387 230 235
3×1×70 3.4 24.9 57.5 3316 0.268 285 295
3×1×95 3.4 26.6 61.2 4153 0.193 340 360
3×1×120 3.4 28.3 64.9 4953 0.153 385 420
3×1×150 3.4 29.9 67.9 5815 0.124 430 475
3×1×185 3.4 31.5 72.0 6947 0.0991 485 550
3×1×240 3.4 34.0 77.6 8704 0.0754 560 650
NFC 33-226 Medium voltage cables (non-aerial) 6/10kV ABC FOR OVERHEAD DISTRIBUTION LINES-Copper Conductor
Number of cores ×  Cross-section  Nominal thickness of Insulation Min. outer diameter over sheath Twisted diameter of cable Approx. weight Max. DC resistance at 20ºC Current rating
Underground
Current rating
In air
No.×mm2 mm mm mm kg/km Ohm/km A A
3×1×50 3.4 23.1 53.4 1739 0.641 180 185
3×1×70 3.4 24.9 57.5 2070 0.443 220 230
3×1×95 3.4 26.6 61.2 2420 0.320 260 280
3×1×120 3.4 28.3 64.9 2769 0.253 300 325
3×1×150 3.4 29.9 67.9 3115 0.206 335 370
3×1×185 3.4 31.5 72.0 3574 0.164 380 425
3×1×240 3.4 34.0 77.6 4267 0.125 440 510
NFC 33-226 Medium voltage cables (non-aerial) 6/10kV ABC FOR OVERHEAD DISTRIBUTION LINES--Aluminium Conductor
Number of cores ×  Cross-section  Nominal thickness of Insulation Min. outer diameter over sheath Twisted diameter of cable Approx. weight Max. DC resistance at 20ºC Current rating
Underground
Current rating
In air
No.×mm2 mm mm mm kg/km Ohm/km A A
3×1×50 4.5 25.5 58.6 2892 0.387 230 245
3×1×70 4.5 27.3 62.7 3626 0.268 280 305
3×1×95 4.5 29.0 66.4 4481 0.193 335 375
3×1×120 4.5 30.7 70.1 5299 0.153 385 425
3×1×150 4.5 32.3 73.1 6176 0.124 430 485
3×1×185 4.5 33.9 77.2 7328 0.0991 490 560
3×1×240 4.5 36.4 82.8 9113 0.0754 560 660
NFC 33-226Medium voltage cables (non-aerial) 8.7/15kV ABC FOR OVERHEAD DISTRIBUTION LINES-Copper Conductor
Number of cores ×  Cross-section  Nominal thickness of Insulation Min. outer diameter over sheath Twisted diameter of cable Approx. weight Max. DC resistance at 20ºC Current rating
Underground
Current rating
In air
No.×mm2 mm mm mm kg/km Ohm/km A A
3×1×50 4.5 25.5 58.6 2028 0.641 180 190
3×1×70 4.5 27.3 62.7 2379 0.443 220 235
3×1×95 4.5 29.0 66.4 2748 0.320 260 290
3×1×120 4.5 30.7 70.1 3115 0.253 300 330
3×1×150 4.5 32.3 73.1 3476 0.206 335 375
3×1×185 4.5 33.9 77.2 3955 0.164 380 430
3×1×240 4.5 36.4 82.8 4676 0.125 440 510
NFC 33-226 Medium voltage cables (non-aerial) 8.7/15kV ABC FOR OVERHEAD DISTRIBUTION LINES--Aluminium Conductor
Number of cores ×  Cross-section  Nominal thickness of Insulation Min. outer diameter over sheath Twisted diameter of cable Approx. weight Max. DC resistance at 20ºC Current rating
Underground
Current rating
In air
No.×mm2 mm mm mm kg/km Ohm/km A A
3×1×50 5.5 28.0 63.4 3180 0.387 230 245
3×1×70 5.5 29.5 67.5 3932 0.268 280 305
3×1×95 5.5 31.2 71.2 4804 0.193 335 375
3×1×120 5.5 32.9 74.9 5639 0.153 385 425
3×1×150 5.5 34.5 77.9 6530 0.124 430 485
3×1×185 5.5 36.1 82.0 7701 0.0991 490 560
3×1×240 5.5 38.6 87.6 9511 0.0754 560 660
NFC 33-226 Medium voltage cables (non-aerial) 12/20kV ABC FOR OVERHEAD DISTRIBUTION LINES-Copper Conductor
Number of cores ×  Cross-section  Nominal thickness of Insulation Min. outer diameter over sheath Twisted diameter of cable Approx. weight Max. DC resistance at 20ºC Current rating
Underground
Current rating
In air
No.×mm2 mm mm mm kg/km Ohm/km A A
3×1×50 5.5 28.0 63.4 2316 0.641 180 190
3×1×70 5.5 29.5 67.5 2685 0.443 220 235
3×1×95 5.5 31.2 71.2 3071 0.320 260 290
3×1×120 5.5 32.9 74.9 3455 0.253 300 330
3×1×150 5.5 34.5 77.9 3830 0.206 335 375
3×1×185 5.5 36.1 82.0 4328 0.164 380 430
3×1×240 5.5 38.6 87.6 5074 0.125 440 510
NFC 33-226 Medium voltage cables (non-aerial) 12/20kV ABC FOR OVERHEAD DISTRIBUTION LINES--Aluminium Conductor
Number of cores ×  Cross-section  Nominal thickness of Insulation Min. outer diameter over sheath Twisted diameter of cable Approx. weight Max. DC resistance at 20ºC Current rating
Underground
Current rating
In air
No.×mm2 mm mm mm kg/km Ohm/km A A
3×1×50 8.0 33.1 75.2 3979 0.387 230 245
3×1×70 8.0 34.9 79.2 4777 0.268 280 305
3×1×95 8.0 36.8 83.4 5725 0.193 335 375
3×1×120 8.0 38.3 86.6 6565 0.153 385 425
3×1×150 8.0 39.9 89.6 7491 0.124 430 485
3×1×185 8.0 41.5 93.7 8707 0.0991 490 560
3×1×240 8.0 44.0 99.3 10579 0.0754 560 660
NFC 33-226 Medium voltage cables (non-aerial) 18/30kV ABC FOR OVERHEAD DISTRIBUTION LINES-Copper Conductor
Number of cores ×  Cross-section  Nominal thickness of Insulation Min. outer diameter over sheath Twisted diameter of cable Approx. weight Max. DC resistance at 20ºC Current rating
Underground
Current rating
In air
No.×mm2 mm mm mm kg/km Ohm/km A A
3×1×50 8.0 33.1 75.2 3115 0.641 180 190
3×1×70 8.0 34.9 79.2 3530 0.443 220 235
3×1×95 8.0 36.8 83.4 3992 0.320 260 290
3×1×120 8.0 38.3 86.6 4381 0.253 300 330
3×1×150 8.0 39.9 89.6 4790 0.206 335 375
3×1×185 8.0 41.5 93.7 5334 0.164 380 430
3×1×240 8.0 44.0 99.3 6143 0.125 440 510

NFC 33-226 Medium voltage cables (non-aerial) 18/30kV ABC FOR OVERHEAD DISTRIBUTION LINES--Aluminium Conductor

Hta S26 Extruded XLPE Insulation Medium Voltage Cable NFC33-226 StandardHta S26 Extruded XLPE Insulation Medium Voltage Cable NFC33-226 Standard

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory
Year of Establishment
2017-10-17
Plant Area
2000 square meters