• Cable Bicapa Covered Cable Two Layers 25kv 70mm2
  • Cable Bicapa Covered Cable Two Layers 25kv 70mm2
  • Cable Bicapa Covered Cable Two Layers 25kv 70mm2
  • Cable Bicapa Covered Cable Two Layers 25kv 70mm2

Cable Bicapa Covered Cable Two Layers 25kv 70mm2

Application: Construction, Underground
Voltage: Low and Medium Voltage Cable
Current: AC Cable
Insulation Material: XLPE
Sheath Material: Crosslinking
Material Shape: Round Wire
Samples:
US$ 0/Meter 1 Meter(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
BICAPA
Wire Core Material
Aluminum
Certification
ISO, CCC, CE, RoHS, VDE
Model
Yjv32
Brand
Jinshui
Destination
Chile
Type
Bicapa
Transport Package
Wooden Drums
Specification
2.2*1.1*1.0*1.1
Trademark
Jinshui
Origin
China
HS Code
8544492100
Production Capacity
50000m/Day

Product Description

Applicable regulations
ANSI/ICEA-S-121-733: Tree Wire and Messenger Supported Spacer Cable.
ANSI/ICEA-T-28-562-2014: Test Method for Measurement of Hot Creep of Polymeric Insulations.
ANSI/ICEA-T-32-645: Test Method for Establishing Volume Resistivity Compatibility of Water Blocking
Components with Extruded Semiconducting Shield Materials.
ANSI/ICEA-T-31-610: Test Method for Conducting Longitudinal Water Penetration Resistance Tests
on Blocked Conductors.
ANSI/ICEA-T-26-465 NEMA WC 54: Guide for frequency of sampling extruded dielectric power,
control, instrumentation, and portable cables for test.
ANSI/ICEA-T-25-425: Guide for establishing stability of volume resistivity for semiconducting polymeric
components of power cables.
IEEE 1142-2009: IEEE Guide for the Selection, Testing, Application, and Installation of Cables having
Radial-Moisture Barriers and/or Longitudinal Water Blocking.
NEMA WC-54-2001/ICEA-T-26-465-2013: Guide for Frequency of Sampling
Extruded Dielectric Power, Control, Instrumentation, and Portable Cables for
Test.Machine Translated by Google
NEMA WC-53-2000/ICEA-T-27-581-2008: Standard Test Methods for Extruded
Dielectric Power, Control, Instrumentation and Portable Cables.
NEMA Standards Publication No. WC-26-2008 EEMAC: Standards Publication
201-2008 Binational Wire and Cable Packaging Standard.
ASTM D1248-16: Standard Specification for Polyethylene Plastics Extrusion Materials for Wire and
Cable.
ASTM D2303-13: Standard Test Methods for Liquid-Contaminant, Inclined-Plane Tracking and Erosion
of Insulating Materials.
ASTM D2132: Test Method for Dust-and-Fog Tracking and Erosion Resistance of Electrical Insulating
Materials.
ASTM D3004 - 08(2013): Standard Specification for Crosslinked and Thermoplastic Extruded Semi
Conducting, Conductor and Insulation Shielding Materials.
ASTM D6095: Standard Test Method for Longitudinal Measurement of Volume Resistivity for Extruded
Crosslinked and Thermoplastic Semiconducting Conductor and Insulation Shielding Materials.
ASTM D2633: Standard Test Methods for Thermoplastic Insulations and Jackets for Wire and Cable.
ASTM B230/B230M: Specification for Aluminum 1350H19 Wire for Electrical Purposes.
ASTM B231/B231M-16: Standard Specification for Concentric-Lay-Stranded Aluminum 1350 Conductors.
ASTM B399/B399M-04(2015): Standard Specification for Concentric-Lay-Stranded Aluminum-Alloy
6201-T81 Conductors.
ASTM B398/B398M: Specification for Aluminum-Alloy 6201-T81 and 6201-T83 Wire for Electrical
Purposes.
ASTM B400: For compact round stranded aluminum 1350 conductors.
ASTM B354: Standard Terminology Relating to Uninsulated Metallic Electrical Conductors.
ASTM G153 - 13: Standard Practice for Operating Enclosed Carbon Arc Light Apparatus for Exposure
of Nonmetallic Materials.
IEEE 4-2013: IEEE Standard for High-Voltage Testing Techniques.
ABNT NBR 11873: Covered cables with polymeric material for aerial distribution networks of electrical
energy fixed in spacers, with voltages from 13.8 kV to 34.5 kV. Covered cables with polymeric material
for overhead distribution /ines in spacers for voltages 13.8kV up to 34.5kV.
EN 50397-1: Covered conductors for overhead lines and the related
accessories for rated voltages above 1kV ac and not exceeding 36kV ac -Machine Translated by Google
Part 1: Covered drivers.
EN 50397-3: Covered conductors for overhead lines and the related
accessories for rated voltages above 1kV ac and not exceeding 36kV ac
Part 3: Guide to Use.
ASTM G155 - 13: Standard Practice for Operating Xenon Arc Light Apparatus for
Exposure of Non-Metallic Materials.
IEC TS 60815-1:2008: Selection and dimensioning of high-voltage insulators intended
for use in polluted conditions - Part 1: Definitions, information and general principles.
IEC TS 60815-3:2008: Selection and dimensioning of high-voltage insulators intended
for use in polluted conditions - Part 3: Polymer insulators for ac systems.
UL 2556: UL: Standard for Safety Wire and Cable Test Methods
Cable Bicapa Covered Cable Two Layers 25kv 70mm2

Cable Bicapa Covered Cable Two Layers 25kv 70mm2Cable Bicapa Covered Cable Two Layers 25kv 70mm2

Cable Bicapa Covered Cable Two Layers 25kv 70mm2


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory
Year of Establishment
2017-10-17
Plant Area
2000 square meters